17600 – System Data
System data consists of 6 bytes. The first byte has the current alarm contact settings. Each
bit corresponds to a contact. Bit 0 (lsb) is the bit for the Power Supply alarm, and bit 3 is
the bit for the 'any' alarm. The next byte is for the installed card inventory. A '0' bit means
the card is installed and a '1' bit means the card is removed. The other bytes are for
internal use.
17601:17603 – Card Data
Each I/O card in the router has an associated TCP port. Card 1 uses port 17601, card 2 uses
17602, and so on. The data is formatted as follows:
• 6 bytes, internal use
• 1 byte, card type
◦ 0xff missing
◦ 0x02 normal
◦ 0x05 reclocked
• SFP data, 256 bytes per SFP, 16 SFPs per card
◦ 128 bytes, SFP ID data
◦ 128 bytes, SFP diagnostic data
Nov 3, 2014 Router Interfaces: MX48 19/25
Table 6: MX48 System Data
Alarms Inventory
Byte Byte
Bit 0 1
0 Alarm 1 Card 1
1 Alarm 2 Card 2
2 Alarm 3 Card 3
3 Alarm 4
4
5
6
7