S e c u r e C o n s o l e S e r v e r M a n u a l , R e v . K
Page 74
Command: #Pn Set 11-bit Parity
Values: n = 0 or 1
Default: 2
Description: #P0 No parity.
#P1 Odd parity.
#P2 Even parity.
Command: #S
x
Enter Setup Password
Values:
x
= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Enters the remote configuration setup password.
Command: #S=
x
Store Setup Password
Values:
x
= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Stores a new remote configuration setup password.
Escape AT Commands
Command: +++AT<CR> Escape Sequence
Values: n/a
Description: Puts the modem in command mode (and optionally issues a command) while remaining online.
Type +++AT and up to six optional command characters; then press ENTER. Used mostly to
issue the hang-up command: +++ATH<CR>.
Command: %%%ATMTSMODEM<CR> Remote Configuration Escape Sequence
Values: n/a
Description: Initiates remote configuration mode while online with remote modem. The remote
configuration escape character (%) is defined in register S13.
V.92 Commands
Command: +MS= Modulation Selection
Values: See description.
Defaults: See description.
Description: This extended-format command selects modulation, enables or disables automode, and
specifies the highest downstream and upstream connection rates using one to four
subparameters. The command syntax is
+MS=[mod][,[automode][,[0][,[max_rate][,[0][,[max_rx_rate]]]]]]<CR>
Subparameters that are not entered retain their current value. Commas separate optional
subparameters, and must be inserted to skip a subparameter. Example: +MS=,0<CR> disables
automode and keeps all other settings at their current values.
+MS=? Reports supported options in the format (list of supported mod values),(list of supported
automode values),(0),(list of supported max_rate values),(0),(list of supported max_rx_rate
values). Example: +MS: (BELL103, V21, BELL212A, V22, V22B, V23C, V32, V32B, V34, V90,
V92), (0, 1), (0), (0-33600), (0), (0- 56000)
+MS? Reports current options in the format mod, automode, 0, max_rate, 0, max_rx_rate.
Example: +MS: V92,1, 0, 31200, 0, 56000.